Article content

Hanan K. Mahmood Nadia F. Salman Dhurgham H. Hasan Khaleefah M. Salih Maryam A. Sadiq Basma T. Mohammad Maryam K. Mohammed Sarwa M. Nahi Sara S. Baqir

Abstract

DNA amplification is known to be the most expensive step during forensic DNA analysis. This study evaluated the half-reaction amplification protocol (12.5 µL PCR product) using DNA amplification kits from Promega PowerPlex® (PowerPlex® 18D System, PowerPlex ®21System, PowerPlex® Fusion System and PowerPlex® Y23 System), which might aid in reducing sample analysis cost by half and allow the analysis of more samples.
A sensitivity study (15 samples) along with testing of various blood stain samples (n=100) that were submitted to the Medico-Legal Directorate laboratory for DNA testing was accomplished to compare the DNA profiles resulting from half-reaction volume procedure to those with full-reaction volume procedure, using three differed methods along with standard protocol to evaluate the effect of half reaction volume with some variables.
Results demonstrated the use of half-reaction amplification protocol preceded by washing step for all aforementioned DNA amplification kits gave a robust and reliable amplification result that aid to increase the number of samples analyzed and decreased the test cost for each kit without compromising the quality of 3DNA profiles obtained.

Downloads

Download data is not yet available.

References

Garibyan L, Avashia N. Research techniques made simple: polymerase chain reaction (PCR). The Journal of investigative dermatology. 2013 Mar;133(3):e6. https://doi.org/10.1038/jid.2013.1

Bej AK, Mahbubani MH, Atlas RM. Amplification of nucleic acids by polymerase chain reaction (PCR) and other methods and their applications. Critical reviews in biochemistry and molecular biology. 1991 Jan 1;26(3-4):301-34. https://doi.org/10.3109/10409239109114071

National Institute of Justice (NIJ), US Department of Justice, Office of Justice Programs, United States of America. Using DNA to Solve Cold Cases: Special Report.

Butts E. Exploring DNA extraction efficiency. InForensics@ NIST 2012 Meeting 2012 Nov 28.

Ensenberger MG, Hill CR, McLaren RS, Sprecher CJ, Storts DR. Developmental validation of the PowerPlex® 21 System. Forensic Science International: Genetics. 2014 Mar 1;9:169-78. https://doi.org/10.1016/j.fsigen.2013.12.005

Oostdik K, Lenz K, Nye J, Schelling K, Yet D, Bruski S, Strong J, Buchanan C, Sutton J, Linner J, Frazier N. Developmental validation of the PowerPlex® Fusion System for analysis of casework and reference samples: A 24-locus multiplex for new database standards. Forensic Science International: Genetics. 2014 Sep 1;12:69-76. https://doi.org/10.1016/j.fsigen.2014.04.013

Jain T, Shrivastava P, Bansal DD, Dash HR, Trivedi VB. PowerPlex Y23 system: a fast, sensitive and reliable Y-STR multiplex system for forensic and population genetic purpose. J Mol Biomark Diagn. 2016;7(3):1-7. https://doi.org/10.4172/2155-9929.1000281

Butler JM. Forensic DNA typing: biology & technology behind STR markers. Academic Press; 2001.

Hoffman NH, Fenger T. Validation of Half-Reaction Amplification Using Promega PowerPlex® 16. Journal of forensic sciences. 2010 Jul;55(4):1044-9. https://doi.org/10.1111/j.1556-4029.2010.01388.x

Barbaro A, Cormaci P. Validation of PowerPlex® Y23 System (promega) using reduced reaction volume. Forensic Science International: Genetics Supplement Series. 2015 Dec 1;5:e373-4. https://doi.org/10.1016/j.fsigss.2015.09.148

Iyavoo S, Cummings S, Wolejko A, Furmanczyk D, Graham R, Myers R, Haizel T. Reduced volume PCR amplification using AmpFℓSTR® Identifiler® kit. Forensic Science International: Genetics Supplement Series. 2015 Dec 1;5:e398-9. https://doi.org/10.1016/j.fsigss.2015.09.157

Akane A, Matsubara K, Nakamura H, Takahashi S, Kimura K. Identification of the heme compound copurified with deoxyribonucleic acid (DNA) from bloodstains, a major inhibitor of polymerase chain reaction (PCR) amplification. Journal of Forensic Science. 1994 Mar 1;39(2):362-72. https://doi.org/10.1520/JFS13607J

Sidstedt M, Hedman J, Romsos EL, Waitara L, Wadsö L, Steffen CR, Vallone PM, Rådström P. Inhibition mechanisms of hemoglobin, immunoglobulin G, and whole blood in digital and real-time PCR. Analytical and bioanalytical chemistry. 2018 Apr 1;410(10):2569-83. https://doi.org/10.1007/s00216-018-0931-z

Article details

Section
Original Article
Copyright Information
Creative Commons License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

     You must read and accept the copyright terms and conditions(click here for copyright terms).

Most read articles by the same author(s)